Wiki

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
resources:eval:user-guides:eval-adtf3175d-nxz-upgrade-firmware [05 Jul 2022 15:45] – changed the config file name in the data_collect firmware update example. Andre Straker-Payneresources:eval:user-guides:eval-adtf3175d-nxz-upgrade-firmware [11 Apr 2023 14:54] – Added wait 60s Andre Straker-Payne
Line 10: Line 10:
  
   * Connect camera - ensure camera network is detected by the PC   * Connect camera - ensure camera network is detected by the PC
-  * Run the following command, using the appropriate firmware filename: **data_collect.exe --ip 10.42.0.1 --fw firmware_upgrade_3123.bin tof-viewer_config.json**+  * Run the following command, using the appropriate firmware filename:  
 +    ''data_collect.exe --ip 10.42.0.1 --fw firmware_upgrade_xxxx.bin tof-viewer_config.json''
  
 {{ :resources:eval:user-guides:running_upgrade_command.png?direct |}} {{ :resources:eval:user-guides:running_upgrade_command.png?direct |}}
Line 35: Line 36:
 {{ :resources:eval:user-guides:puttyinnxp.png?direct |}} {{ :resources:eval:user-guides:puttyinnxp.png?direct |}}
   * Run the following commands to upgrade firmware (replace upgrade_firmware_xxxx.bin with your version)   * Run the following commands to upgrade firmware (replace upgrade_firmware_xxxx.bin with your version)
-    * cd Workspace/ToF/build/examples/data_collect +    * ''cd Workspace/ToF/build/examples/data_collect'' 
-    * ./data_collect --fw /boot/firmware_upgrade_xxxx.bin config/config_default.json+    * ''./data_collect --fw /boot/firmware_upgrade_xxxx.bin config/config_default.json''
  
 {{ :resources:eval:user-guides:putty_running_cmd.png?direct |}} {{ :resources:eval:user-guides:putty_running_cmd.png?direct |}}
 {{ :resources:eval:user-guides:putty_cmd_done.png?direct |}} {{ :resources:eval:user-guides:putty_cmd_done.png?direct |}}
 +  * **Wait 60 seconds**
   * Power cycle camera   * Power cycle camera
   * Run GUI and check if the ADSD3500 version number has updated   * Run GUI and check if the ADSD3500 version number has updated
resources/eval/user-guides/eval-adtf3175d-nxz-upgrade-firmware.txt · Last modified: 11 Apr 2023 14:54 by Andre Straker-Payne