resources:eval:user-guides:circuits-from-the-lab:cn0251 [03 Jan 2021 21:55] – fix links Robin Getzresources:eval:user-guides:circuits-from-the-lab:cn0251 [17 Feb 2021 09:44] – [Getting Started with ADALM2000 and Scopy] Harvey John De Chavez
Line 18: Line 18:
   * ±15V Dual Power Supply   * ±15V Dual Power Supply
   * [[ftp://ftp.analog.com/pub/cftl/CN0251/|CN-0251 Evaluation Software]]   * [[ftp://ftp.analog.com/pub/cftl/CN0251/|CN-0251 Evaluation Software]]
-  * [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] +  * [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html|ADALM2000]] 
-  * [[https://www.digilentinc.com/Data/Products/WAVEFORMS/digilent.waveforms_v2.4.4.exe|Digilent WaveForms Software]] +  * [[:university:tools:m2k:scopy|Scopy Software]] 
-    * [[https://docs.google.com/file/d/0B0HvJpwX5NzPTWRFRzcyWUprc2M/edit?usp=sharing|CN0251 WaveForms Project file]]+    * {{ :resources:eval:user-guides:circuits-from-the-lab:cn0251:siggen.zip |Scopy Project File}}
   * PC with the following //Minimum Requirements//   * PC with the following //Minimum Requirements//
     * Windows XP Service Pack 2 (32-bit)     * Windows XP Service Pack 2 (32-bit)
Line 33: Line 33:
   * The ±15V Dual Power supply powers the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** via the screw terminals at **J4**.   * The ±15V Dual Power supply powers the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** via the screw terminals at **J4**.
   * The [[adi>EVAL-SDP-CB1Z|EVAL-SDP-CB1Z]] **(SDP-B Board)** connects to the PC via the USB Type A to USB Mini-B cable.   * The [[adi>EVAL-SDP-CB1Z|EVAL-SDP-CB1Z]] **(SDP-B Board)** connects to the PC via the USB Type A to USB Mini-B cable.
-  * The [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] connects to the PC via the USB Type-A to USB Micro-B cable. +  * The [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html|ADALM2000]] connects to the PC via the USB Type-A to USB Micro-B cable. 
-  * The [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] connects to the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** via the screw terminals at **J1**.\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-test_setup.png?nolink&|}}+  * The [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html|ADALM2000]] connects to the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** via the screw terminals at **J1**.\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-test_setup.png?nolink&|}}
  
 ---- ----
Line 42: Line 42:
     * **JP1** and **JP2** configure the analog inputs for single-ended or differential inputs     * **JP1** and **JP2** configure the analog inputs for single-ended or differential inputs
     * **JP3** and **JP4** configure the gain of the [[adi>AD8475|AD8475]] to be 0.4x or 0.8x\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-jumpers.png?nolink|}}\\ \\      * **JP3** and **JP4** configure the gain of the [[adi>AD8475|AD8475]] to be 0.4x or 0.8x\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-jumpers.png?nolink|}}\\ \\ 
-  - Connect the [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] to the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** as depicted in the figures below.  +  - Connect the [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html#eb-overview|ADALM2000]] to the [[adi>EVAL-CN0251-SDPZ|EVAL-CN0251-SDPZ]] **(CN-0251 Board)** as depicted in the figures below.  
     * The waveform outputs should be connected to **J1:2 (IN1-)** and **J1:3 (IN2+)** of the **CN-0251 Board**.     * The waveform outputs should be connected to **J1:2 (IN1-)** and **J1:3 (IN2+)** of the **CN-0251 Board**.
-    * The [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] ground should be connected to **AGND** of the **CN-0251 Board**.\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-discovery.png?nolink|}}\\ \\ +    * The [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html#eb-overview|ADALM2000]] ground should be connected to **AGND** of the **CN-0251 Board**.\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-discovery.png?nolink|}}\\ \\ 
   - Connect the +6V Power Supply to the screw terminal at **J3**.   - Connect the +6V Power Supply to the screw terminal at **J3**.
   - Connect the ±15V Power Supply to the screw terminal at **J4**.   - Connect the ±15V Power Supply to the screw terminal at **J4**.
Line 52: Line 52:
 ---- ----
  
-===== Setting up Digilent WaveForms ===== +===== Getting Started with ADALM2000 and Scopy ===== 
-  - Install [[https://www.digilentinc.com/Data/Products/WAVEFORMS/digilent.waveforms_v2.4.4.exe|Digilent WaveForms Software]] +  - Use the USB Type-A to USB Micro-B cable to connect the [[adi>en/design-center/evaluation-hardware-and-software/evaluation-boards-kits/ADALM2000.html#eb-overview|ADALM2000]] to the PC. A detailed guide on how to start ADALM2000 and install [[:university:tools:m2k:scopy|Scopy]] can be found [[:university:tools:m2k:users|here]]. 
-  - Use the USB Type-A to USB Micro-B cable to connect the [[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,842,1018&Prod=ANALOG-DISCOVERY|Analog Discovery]] to the PC +  - Upon connecting the ADALM2000 to Scopy, load the project file named //SigGen.ini// then click on the **Signal Generator** tab on the left pane. \\ {{ :resources:eval:user-guides:circuits-from-the-lab:cn0251:scopy.png?600 |}} 
-  - Open the file named [[https://docs.google.com/file/d/0B0HvJpwX5NzPTWRFRzcyWUprc2M/edit?usp=sharing|cn0251_demo.dwfawg]]\\ \\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-waveforms.png?840|}}\\ \\  +  - Click the **Run button**.\\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:run.png?80 |}}
-  - Click the **Run All Button**\\ {{:resources:eval:user-guides:circuits-from-the-lab:cn0251:cn0251-run_all.png?nolink|}}+
  
 ---- ----
resources/eval/user-guides/circuits-from-the-lab/cn0251.txt · Last modified: 30 Jul 2021 07:26 by Victor Calinao, Jr