Wiki

This version (20 Oct 2015 13:54) was approved by Dragos Bogdan.The Previously approved version (13 Mar 2015 17:08) is available.Diff

Filter response

The following transmitter and receiver FIR filters were designed using the AD9361 Filter Design Wizard (for more information, consult the MATLAB Filter Design Wizard for AD9361 wiki page http://wiki.analog.com/resources/eval/user-guides/ad-fmcomms2-ebz/software/filters).

The response was measured on an AD-FMCOMMS3-EBZ using the bare-metal AD9361 software running in Linux user space, a spectrum analyzer and the ADI VisualAnalog software.

Updated on October 20, 2015

Description Filter settings TX Filter response TX & RX Filter response

Sampl. Freq.: 232748 Hz

LO Freq.: 70 MHz

DDS Freq.: 70000 Hz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_232748.zip

Sampl. Freq.: 245760 Hz

LO Freq.: 2415 MHz

DDS Freq.: 70000 Hz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_245760.zip

Sampl. Freq.: 256000 Hz

LO Freq.: 460 MHz

DDS Freq.: 70000 Hz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_256e3.zip

Sampl. Freq.: 15.360 MHz

LO Freq.: 806 MHz

DDS Freq.: 4 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_15.36e6.zip

Sampl. Freq.: 15.360 MHz

LO Freq.: 2450 MHz

DDS Freq.: 4 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_15.36e6.zip

Sampl. Freq.: 22 MHz

LO Freq.: 2427 MHz

DDS Freq.: 6 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_22e6.zip

Sampl. Freq.: 50 MHz

LO Freq.: 1000 MHz

DDS Freq.: 12 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_50e6.zip

Sampl. Freq.: 60 MHz

LO Freq.: 4000 MHz

DDS Freq.: 12 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_60e6.zip

Sampl. Freq.: 61.44 MHz

LO Freq.: 6000 MHz

DDS Freq.: 12 MHz

DDS Scale: 0.250 for each tone*

DDS Phase: 90 degrees for I tones, 0 degrees for Q tones*

fir_61.44e6.zip

*Note: The DDS for a channel consists of two tones.