Wiki

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
university:tools:m2k:scopy:test-cases:signal-generator [26 Jul 2017 10:04] – created Dann Kristofer Bautistauniversity:tools:m2k:scopy:test-cases:signal-generator [17 Jan 2020 07:49] (current) – [D. Additional Features] Pop Andreea
Line 2: Line 2:
 \\ \\
 ====== Signal Generator - Test Case ====== ====== Signal Generator - Test Case ======
-====== Voltmeter - Test Case ====== 
  
 ===== Initial Setup ===== ===== Initial Setup =====
Line 31: Line 30:
 | Checking increment/decrement value of Amplitude and Frequency; ±1 unit on least significant digit | 4. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step4.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| | Checking increment/decrement value of Amplitude and Frequency; ±1 unit on least significant digit | 4. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step4.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 5. Change the voltage or frequency value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step5.png?200 |}}| The Amplitude value should change accordingly with a ±1 unit on the least significant digit from 1uV to 10V. The frequency value should change accordingly with a ±1 unit on the least significant digit from 1mHz to 20MHz.The graphical representation should follow accordingly| | ::: | 5. Change the voltage or frequency value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step5.png?200 |}}| The Amplitude value should change accordingly with a ±1 unit on the least significant digit from 1uV to 10V. The frequency value should change accordingly with a ±1 unit on the least significant digit from 1mHz to 20MHz.The graphical representation should follow accordingly|
-| Checking increment/decrement value of the Offset and Phase; ±1V and ±1°| 6. Set the knob without the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step6.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| +| Checking increment/decrement value of the Offset Voltage and Phase; ±1V and ±45°| 6. Set the knob without the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step6.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| 
-| ::: | 7. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step7.png?200 |}}| The Offset voltage value should change accordingly with ±1 increment/decrement from -5V to 5V. The phase value should change accordingly with a ±1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly| +| ::: | 7. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step7.png?200 |}}| The Offset voltage value should change accordingly with ±1 increment/decrement from -5V to 5V. The phase value should change accordingly with a ±45 increment/decrement from 0° to 360°.The graphical representation should follow accordingly| 
-| Checking increment/decrement value of Offset voltage and Phase; ±100mV and ±0.1°| 8. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step8.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| +| Checking increment/decrement value of Offset voltage and Phase; ±100mV and ±1°| 8. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step8.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| 
-| ::: | 9. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step9.png?200 |}}| The Offset voltage value should change accordingly with ±.1 increment/decrement from -5V to 5V. The phase value should change accordingly with ±.1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly|+| ::: | 9. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step9.png?200 |}}| The Offset voltage value should change accordingly with ±.1 increment/decrement from -5V to 5V. The phase value should change accordingly with ±1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly|
 | ::: | 10. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step10.png?200 |}}| | ::: | 10. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step10.png?200 |}}|
-::: | 11. Set the signal generator’s waveform type: Sinewave, Amplitude 2V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 5ms.| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step11.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 5ms, Frequency: 200Hz, Peak-peak: 1.9V to 2.1V+Testing Sinewave Waveform | 11. Set the signal generator’s waveform type: Sinewave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 5ms.| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step11.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 5ms, Frequency: 200Hz, Peak-peak: 4.8V to 5.2V
-| ::: | 12. Set the signal generator’s waveform type: Sinewave, Amplitude 2V, Frequency: 20kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 50us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step12a.png?200 |}}{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step12b.png?200 |}}| In the signal generator window, there should be 8 sinewaves with 2V peak to peak amplitude. The measurement reading on Oscilloscope should be: Period: 50us, Frequency: 20kHz, Peak-peak: 1.9V to 2.1V+| ::: | 12. Set the signal generator’s waveform type: Sinewave, Amplitude 10V, Frequency: 500kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step12a.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 2.000us, Frequency: 500 kHz, Peak-peak: 9.6V to 10.2V| 
-::: 13. Set the signal generator’s waveform type: Square wave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 5ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step13.png?200 |}}| Use the Oscilloscope’s cursor to check the peak to peak value of the Square wave generated, do not include the inherent overshoot of the signal. The measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.5V| +| ::: | 13. Set the signal generator’s waveform type: Sinewave, Amplitude 10V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 200ns|  {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step13.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 200ns, Frequency: 5MHz, Peak-peak: 8.9V to 9.2V
-| ::: | 14. Set the signal generator’s waveform type: Square wave, Amplitude 10V, Frequency: 100kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 5us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step14.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 9.8V to 10.2V and Min/Max: ±4.9V+Testing Square Waveform 14. Set the signal generator’s waveform type: Square wave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 5ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step14.png?200 |}}| Use the Oscilloscope’s cursor to check the peak to peak value of the Square wave generated, do not include the inherent overshoot of the signal. The measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.5V| 
-| ::: | 15. Set the signal generator’s waveform type: Triangle, Amplitude 5V, Frequency: 500Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step15.png?200 |}}| Oscilloscope’s measurement should be Period: 2.000ms, Frequency: 500Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| +| ::: | 15. Set the signal generator’s waveform type: Square wave, Amplitude 10V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step15.png?200 |}}| Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 9.8V to 10.2V and Min/Max: ±5V| 
-| ::: | 16. Set the signal generator’s waveform type: Triangle, Amplitude 8V, Frequency: 2MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step16.png?200 |}} | Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 7.8V to 8.2V and Min/Max: +/- 4.9V| +| ::: | 16Set the signal generator’s waveform type: Square wave, Amplitude 7V, Duty Cycle: 20%, Frequency: 100 kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step16.png?200 |}}| Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 6.8V to 7.2V and Min/Max: ±3.5V, +Duty Cycle: 20%, -Duty Cycl: 80%
-::: 17. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 5V, Frequency: 500Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 500us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step17.png?200 |}}| Oscilloscope’s measurement should be Period: 2.000ms, Frequency: 500Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V+| ::: | 17. Repeat step 16 with varying duty cycle from 1% to 99% | |Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 6.8V to 7.2V and Min/Max: ±5V and the varying ±Duty Cycle| 
-| ::: | 18. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 5V, Frequency: 500kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 5us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step18.png?200 |}}| Oscilloscope’s measurement should be Period: 2.000us, Frequency: 500kHz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V+| Testing Triangle Waveform | 18. Set the signal generator’s waveform type: Triangle, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step18.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| 
-::: 19. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step19.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| +| ::: | 19. Set the signal generator’s waveform type: Triangle, Amplitude 8V, Frequency: 2MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step19.png?200 |}} | Oscilloscope’s measurement should be Period: 500.000ns, Frequency: 2MHz, peak to peak value: 7.8V to 8.2V and Min/Max: +/- 3.9V| 
-| ::: | 20. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step20.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal|+Testing Rising Ramp Sawtooth Waveform 20. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step20.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.7V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal
 +| ::: | 21. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step21.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal
 +Testing Falling Ramp Sawtooth Waveform 22. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step22.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| 
 +| ::: | 23. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step23.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal
 +| Testing Trapezoidal waveform | 24. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 5V, Rise Time: 1us, Fall Time: 1us, Hold High Time: 1us, Hold Low time Time: 1us. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 1us | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step24.png?200 |}}|  Oscilloscope’s measurement should be Period: 4.000us, Frequency: 250kHz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6. | 
 +| ::: | 25. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 10V, Rise Time: 1us, Fall Time: 1us, Hold High Time: 1us, Hold Low time Time: 1us. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 1us | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step25.png?200 |}}|  Oscilloscope’s measurement should be Period: 4.000us, Frequency: 250kHz, peak to peak value: 9.6V to 10.4V and Min/Max: ±4.8V to ±5.2. | 
 +| ::: | 26. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 10V, Rise Time: 200ns, Fall Time: 200ns, Hold High Time: 200ns, Hold Low time: 200ns. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 200ns | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step26.png?200 |}}|  Oscilloscope’s measurement should be Period: 800ns, Frequency: 1.250MHz, peak to peak value: 9.6V to 10.4V and Min/Max: ±4.8V to ±5.2. |
 </hidden> </hidden>
- 
- 
 ==== B. Channel 2 Operation==== ==== B. Channel 2 Operation====
 <hidden> <hidden>
-^ Description                           ^ Test Steps     ^ Steps Resources ^ Expected Results ^   +^ Description ^ Test Steps ^ Steps Resources ^ Expected Results ^  
- +| Testing the constant voltage generator| 1. Turn on channel 2 and view the configuration window by clicking the on/off button and menu button respectively. Choose Constant from the configuration menu |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-constant_waveform-step1.png?200 |}} | The interface should look like in the "Step Resources" picture (left side)|
-| Testing the constant voltage generator| 1. Turn on channel 2 and view the configuration window by clicking the on/off button and menu button respectively. Choose Constant from the configuration menu |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-constant_waveform-step1.png?200|}} | The interface should look like in the "Step Resources" picture (left side)|+
 | Checking increment/decrement value; ±1V | 2. Set the knob to ± 1V interval. No orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step2.png?200|}}| The interface should look like in the "Step Resources" picture (left side)| | Checking increment/decrement value; ±1V | 2. Set the knob to ± 1V interval. No orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step2.png?200|}}| The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 3. Change the voltage value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step3.png?200|}}|The voltage value should change accordingly with an increment or decrement of ±1V from -5V to 5V. The graphical representation should follow accordingly| | ::: | 3. Change the voltage value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step3.png?200|}}|The voltage value should change accordingly with an increment or decrement of ±1V from -5V to 5V. The graphical representation should follow accordingly|
Line 66: Line 68:
 | Checking increment/decrement value of Amplitude and Frequency; ±1 unit on least significant digit | 4. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step4.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| | Checking increment/decrement value of Amplitude and Frequency; ±1 unit on least significant digit | 4. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step4.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 5. Change the voltage or frequency value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step5.png?200 |}}| The Amplitude value should change accordingly with a ±1 unit on the least significant digit from 1uV to 10V. The frequency value should change accordingly with a ±1 unit on the least significant digit from 1mHz to 20MHz.The graphical representation should follow accordingly| | ::: | 5. Change the voltage or frequency value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step5.png?200 |}}| The Amplitude value should change accordingly with a ±1 unit on the least significant digit from 1uV to 10V. The frequency value should change accordingly with a ±1 unit on the least significant digit from 1mHz to 20MHz.The graphical representation should follow accordingly|
-| Checking increment/decrement value of the Offset and Phase; ±1V and ±1°| 6. Set the knob without the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step6.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| +| Checking increment/decrement value of the Offset and Phase; ±1V and ±45°| 6. Set the knob without the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step6.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| 
-| ::: | 7. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step7.png?200 |}}| The Offset voltage value should change accordingly with ±1 increment/decrement from -5V to 5V. The phase value should change accordingly with a ±1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly| +| ::: | 7. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step7.png?200 |}}| The Offset voltage value should change accordingly with ±1 increment/decrement from -5V to 5V. The phase value should change accordingly with a ±45 increment/decrement from 0° to 360°.The graphical representation should follow accordingly| 
-| Checking increment/decrement value of Offset voltage and Phase; ±100mV and ±0.1°| 8. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step8.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| +| Checking increment/decrement value of Offset voltage and Phase; ±100mV and ±1°| 8. Set the knob to with the orange dot on the center. |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step8.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)| 
-| ::: | 9. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step9.png?200 |}}| The Offset voltage value should change accordingly with ±.1 increment/decrement from -5V to 5V. The phase value should change accordingly with ±.1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly|+| ::: | 9. Change the Offset voltage or Phase value using the up and down arrow | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step9.png?200 |}}| The Offset voltage value should change accordingly with ±.1 increment/decrement from -5V to 5V. The phase value should change accordingly with ±1 increment/decrement from 0° to 360°.The graphical representation should follow accordingly|
 | ::: | 10. Connect AWG ch2 to scope ch2+ and scope ch2- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step10.png?200 |}}| | ::: | 10. Connect AWG ch2 to scope ch2+ and scope ch2- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step10.png?200 |}}|
-::: | 11. Set the signal generator’s waveform type: Sinewave, Amplitude 2V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 5ms.| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step11.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 5ms, Frequency: 200Hz, Peak-peak: 1.9V to 2.1V+Testing Sinewave Waveform | 11. Set the signal generator’s waveform type: Sinewave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 1ms.| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step11.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 5ms, Frequency: 200Hz, Peak-peak: 4.8V to 5.2V
-| ::: | 12. Set the signal generator’s waveform type: Sinewave, Amplitude 2V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 500mV/div, trigger mode: Auto and time base: 50us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step12.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 200ns, Frequency: 5MHz, Peak-peak: 1.9V to 2.1V+| ::: | 12. Set the signal generator’s waveform type: Sinewave, Amplitude 10V, Frequency: 500kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-different_waveforms-step12a.png?200 |}}| The measurement reading on Oscilloscope should be: Period: 2.000us, Frequency: 500 kHz, Peak-peak: 9.6V to 10.2V| 
-::: 13. Set the signal generator’s waveform type: Square wave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 10ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step13.png?200 |}}| Use the Oscilloscope’s cursor to check the peak to peak value of the Square wave generated, do not include the inherent overshoot of the signal. The measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.5V| +| ::: | 13. Set the signal generator’s waveform type: Sinewave, Amplitude 10V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step13.png?200 |}} | The measurement reading on Oscilloscope should be: Period: 200ns, Frequency: 5MHz, Peak-peak: 8.9V to 9.2V
-| ::: | 14. Set the signal generator’s waveform type: Square wave, Amplitude 9V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step14.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 8.8V to 9.2V and Min/Max: ±4.5V+Testing Square Waveform 14. Set the signal generator’s waveform type: Square wave, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 5ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step14.png?200 |}}| Use the Oscilloscope’s cursor to check the peak to peak value of the Square wave generated, do not include the inherent overshoot of the signal. The measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.5V| 
-| ::: | 15. Set the signal generator’s waveform type: Triangle, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step15.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| +| ::: | 15. Set the signal generator’s waveform type: Square wave, Amplitude 10V, Frequency: 5MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 2V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step15.png?200 |}}| Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 9.8V to 10.2V and Min/Max: ±5V| 
-| ::: | 16. Set the signal generator’s waveform type: Triangle, Amplitude 8V, Frequency: 2MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step16.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 7.8V to 8.2V and Min/Max: +/- 4.9V+| ::: | 16Set the signal generator’s waveform type: Square wave, Amplitude 7V, Duty Cycle: 20%, Frequency: 100 kHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step16.png?200 |}}| Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 6.8V to 7.2V and Min/Max: ±5V, +Duty Cycle: 20%, -Duty Cycl: 80%
-::: 17. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step17.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.7V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal | +| ::: | 17. Repeat step 16 with varying duty cycle from 1% to 99% | |Oscilloscope’s measurement should be Period: 200ns, Frequency: 5MHz, peak to peak value: 6.8V to 7.2V and Min/Max: ±5V and the varying ±Duty Cycle| 
-| ::: | 18. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step18.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal| +| Testing Triangle Waveform | 18. Set the signal generator’s waveform type: Triangle, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step18.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| 
-::: 19. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step19.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| +| ::: | 19. Set the signal generator’s waveform type: Triangle, Amplitude 10V, Frequency: 2MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 100ns| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step19.png?200 |}} | Oscilloscope’s measurement should be Period: 500.000ns, Frequency: 2MHz, peak to peak value: 8.8V to 9V. | 
-| ::: | 20. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step20.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal| +Testing Rising Ramp Sawtooth Waveform 20. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step20.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.7V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal| 
 +| ::: | 21. Set the signal generator’s waveform type: Rising Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step21.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal| 
 +Testing Falling Ramp Sawtooth Waveform 22. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 5V, Frequency: 200Hz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 2ms| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step22.png?200 |}}| Oscilloscope’s measurement should be Period: 5.000ms, Frequency: 200Hz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6V| 
 +| ::: | 23. Set the signal generator’s waveform type: Falling Ramp Sawtooth, Amplitude 8V, Frequency: 1MHz, offset: 0V and Phase: 0 degrees. Set the Oscilloscope’s Volts/div: 1V/div, trigger mode: Auto and time base: 1us| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step23.png?200 |}}| Oscilloscope’s measurement should be Period: 1.000us, Frequency: 1MHz, peak to peak value: 7.8V to 8.2V and Min/Max: ±3.9V to ±4.1V. Use the Oscilloscope’s cursor to disregard the overshoot of the signal| 
 +| Testing Trapezoidal waveform | 24. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 5V, Rise Time: 1us, Fall Time: 1us, Hold High Time: 1us, Hold Low time Time: 1us. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 1us | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step24.png?200 |}} | Oscilloscope’s measurement should be Period: 4.000us, Frequency: 250kHz, peak to peak value: 4.8V to 5.2V and Min/Max: ±2.4V to ±2.6. | 
 +| ::: | 25. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 10V, Rise Time: 1us, Fall Time: 1us, Hold High Time: 1us, Hold Low time Time: 1us. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 1us | {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step25.png?200 |}} | Oscilloscope’s measurement should be Period: 4.000us, Frequency: 250kHz, peak to peak value: 9.6V to 10.4V and Min/Max: ±4.8V to ±5.2. | 
 +| ::: | 26. Set the signal generator’s waveform type: Trapezoidal, Amplitude: 10V, Rise Time: 200ns, Fall Time: 200ns, Hold High Time: 200ns, Hold Low time: 200ns. Set the Oscilloscope’s Volt/div: 2V, Trigger Mode: Auto and Time Base: 200ns |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_2-different_waveforms-step26.png?200 |}} | Oscilloscope’s measurement should be Period: 800ns, Frequency: 1.250MHz, peak to peak value: 9.6V to 10.4V and Min/Max: ±4.8V to ±5.2. |
 </hidden> </hidden>
- 
 ==== C. Channel 1 and Channel 2 Operation==== ==== C. Channel 1 and Channel 2 Operation====
 <hidden> <hidden>
Line 93: Line 99:
 | Test different waveforms for both channels simultaneously| 1. Turn on channels 1 and 2 and view the configuration window by clicking the on/off button then the menu button. Choose waveform from the configuration menu for both channels |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step1.png?200 |}} | The interface should look like in the "Step Resources" picture (left side)| | Test different waveforms for both channels simultaneously| 1. Turn on channels 1 and 2 and view the configuration window by clicking the on/off button then the menu button. Choose waveform from the configuration menu for both channels |{{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step1.png?200 |}} | The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 2. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd. Connect AWG ch2 to scope ch2+ and scope ch2- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step2.png?200 |}}| | ::: | 2. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd. Connect AWG ch2 to scope ch2+ and scope ch2- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step2.png?200 |}}|
-| Test phase configuration| 3. Set signal generator’s channel 1 to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 0°. Set signal generator’s channel to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 180°. Set Oscilloscope’s both channel to Time Base: 200us, Volts/Div: 1V| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step3.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|+| Test phase configuration| 3. Set signal generator channels and 2 to either Sine or Triangle waveform type, they should be the same. For channel 1 set Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 0°. Set signal generator’s channel to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 180°. Set Oscilloscope’s both channel to Time Base: 200us, Volts/Div: 1V| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step3.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 4. Run Oscilloscope, add channel with an input function: f(t) = sin(t1) + sin(t0).| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step4.png?200 |}}| The new plot’s value should be very close to 0V ranging around -0.2V to 0.2V | | ::: | 4. Run Oscilloscope, add channel with an input function: f(t) = sin(t1) + sin(t0).| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step4.png?200 |}}| The new plot’s value should be very close to 0V ranging around -0.2V to 0.2V |
-| ::: | 5. Set signal generator’s channel 1 to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 0°. Set signal generator’s channel to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 360°. Set Oscilloscope’s both channel to Time Base: 200us, Volts/Div: 1V| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step5.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|+| ::: | 5. Set signal generator channels and 2 to either Sine or Triangle waveform type, they should be the same. For channel 1 set Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 0°. Set signal generator’s channel to Amplitude: 5V, Frequency: 5kHz, offset: 0V and phase: 360°. Set Oscilloscope’s both channel to Time Base: 200us, Volts/Div: 1V| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step5.png?200 |}}| The interface should look like in the "Step Resources" picture (left side)|
 | ::: | 6. Run Oscilloscope, add channel with an input function: f(t) = sin(t1) - sin(t0).| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step6.png?200 |}}| The new plot’s value should be very close to 0V ranging around -0.2V to 0.2V | | ::: | 6. Run Oscilloscope, add channel with an input function: f(t) = sin(t1) - sin(t0).| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1and2-different_waveform-step6.png?200 |}}| The new plot’s value should be very close to 0V ranging around -0.2V to 0.2V |
 +</hidden>
  
 +==== D. Additional Features====
 +<hidden>
 +^ Description ^ Test Steps ^ Steps Resources ^ Expected Results ^ 
 +| Noise | 1. Turn on Signal Generator’s channel 1 and set the following parameter, Waveform Type: Square Wave, Amplitude: 3V, Offset: 1.5V, Frequency: 1kHz, Phase: 0degrees and Duty Cycle: 50% |{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Noise_step1.png?100 |}}| The interface should look like in the "Step Resources" picture (left side). |
 +| ::: | 2. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step6.png?100 |}}| Check in the Oscilloscope if the Square Wave signal generated is from 0V to 3V.|
 +| ::: | 3. Choose Uniform Noise Type in the dropdown menu and set it to 500mV|{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Noise_step3.png?100 |}}| The interface should look like in the "Step Resources" picture (left side) |
 +| ::: | 4. Set the Oscilloscope’s setting to Time Base: 100us, Volts/Div: 500mV/Div; Using the cursors measure the noise generated in the square waveform |{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Noise_step4.png?100 |}}| The measured voltage should be close to 500mV. Check the step resource picture for reference. |
 +| ::: | 5. Repeat steps 3 and 4 using different Noise Amplitude [1V, 1.5V, 2V and 2.5V] | | The measured voltage should be close to the desired noise voltage. |
 +| ::: | 6. Repeat steps 3 to 5 using different Noise type | | The measured voltage should be close to the desired noise voltage. |
 +| Buffer | 1. Download {{:university:tools:m2k:scopy:test-cases:signal_generator_buffer_test.zip|buffer test files }} . Open Signal Generator Instrument and click the Buffer Tab|{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Buffer_step1.png?100 |}} | Refer to the Step Resource Image for reference|
 +| ::: | 2. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step6.png?100 |}}| |
 +| Test .csv file | 3. Load the .csv file from the downloaded .zip file |{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Buffer_step3.png?100 |}} | The signal generated should be a stair step signal. |
 +| Test .mat file | 4. Load the .mat file from the downloaded .zip file. Set the frequency to 20kHz, and the time base of Oscilloscope to 10ms. |{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Buffer_step4.png?100 |}}| The signal generated should be a sine wave signal. |
 +| Math | 1. Open Signal Generator Instrument and click the Math tab | {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Math_step1.png?100 |}}| Refer to the Step Resource image for reference. |
 +| ::: | 2. Connect AWG ch1 to scope ch1+ and scope ch1- to gnd| {{ :university:tools:m2k:scopy:test-cases:signal_generator-channel_1-constant_waveform-step6.png?100 |}}| |
 +| Generate Sine waves | 3. In the Signal Generator Math Function tab, set frequency to 100Hz, and type in the function box 5*sin(t) and click apply. In the Oscilloscope instrument set Volts/div: 1V/div, Trigger: Auto, Time base: 2ms| {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Math_step3.png?100 |}}| The generated sine wave signal should have the following parameters, peak to peak: 9.6Vpp to 10.4Vpp, frequency: 100Hz, and period: 10ms. Refer to the Step resource image for reference|
 +| ::: | 4. In the Signal Generator Math Function tab, set frequency to 1kHz, and type in the function box 4*sin(10*t) and click apply. In the Oscilloscope instrument set Volts/div: 1V/div, Trigger: Auto, Time base: 20us| {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Math_step4.png?100 |}}| The generated sine wave signal should have the following parameters, peak to peak: 7.6Vpp to 8.4Vpp, frequency: 10kHz, and period: 100us. Refer to the Step resource image for reference|
 +| ::: | 5. In the Signal Generator Math Function tab, set frequency to 100kHz, and type in the function box 3*sin(50*t) and click apply. In the Oscilloscope instrument set Volts/div: 1V/div, Trigger: Auto, Time base: 100ns| {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Math_step5.png?100 |}}| The generated sine wave signal should have the following parameters, peak to peak: 5.6Vpp to 6.4Vpp, frequency: 5MHz, and period: 200ns. Refer to the Step resource image for reference|
 +| Generate Square waves | 6. In the Signal Generator Math Function tab, set frequency to 500kHz, and type in the function box 4*sin(t) + 4*sin(3*t)/3 + 4*sin(5*t)/5 + 4*sin(7*t)/7 + 4*sin(9*t)/9 + 4*sin(11*t)/11 (you can copy and paste the text to Scopy) and click apply. In the Oscilloscope instrument set Volts/div: 1V/div, Trigger: Auto, Time base: 500ns| {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_Math_step6.png?100 |}}| The generated square wave signal should have the following parameters, peak to peak: 7Vpp to 7.4Vpp, frequency: 500kHz, and period: 2us. Refer to the Step resource image for reference|
 +|Waveform Phase – Seconds| 1. Open Waveform tab. Set frequency to 500Hz. Set Phase to 90 degrees. Then change phase unit to seconds. | {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_phase_step1.png?100 |}}| The value of Phase should automatically change to 500us that is 90 degrees in seconds for a frequency of 500Hz. |
 +|:::| 2. Increase and decrease the value of phase.|  | The display should follow accordingly.|
 +|::: | 3. Increase phase value to 1.5 ms. Then change again the unit to degrees.| {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_phase_step3.png?100 |}} | The value should now be 270 degrees. |
 +|:::| 4. Change frequency to 1 MHz. Then set phase to 1us. This corresponds to a full period of a 1MHz frequency. | {{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_phase_step4.png?100 |}}| The interface should look like in steps resources picture.|
 +|:::| 5. Change phase unit to degrees. |{{ :university:tools:m2k:scopy:test-cases: signal_generator-additional_feature_phase_step5.png?100 |}} | The value should be 360 degrees. | 
 </hidden> </hidden>
 +
 +
 +Test Results will be recorded in the following document: {{ :university:tools:m2k:scopy:test-cases:signal_generator_-_test_case.xlsx |Signal Generator Test Case}}
 +
 +\\
 +**Return to Test Cases [[university:tools:m2k:scopy:test-cases|Table of Contents]]**
  
university/tools/m2k/scopy/test-cases/signal-generator.1501056283.txt.gz · Last modified: 26 Jul 2017 10:04 by Dann Kristofer Bautista