Wiki

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
university:courses:electronics:electronics-lab-8 [24 Jul 2017 15:21] – change amplitude value to peak-peak Antoniu Miclausuniversity:courses:electronics:electronics-lab-8 [29 Aug 2017 14:32] – add xy plot Antoniu Miclaus
Line 23: Line 23:
  
 ===== Hardware Setup: ===== ===== Hardware Setup: =====
 +
 +{{:university:courses:electronics:bjt_stabilized_cs-bb.png|}}
 +
 +<WRAP centeralign> Figure 2 Stabilized current source Breadboard Circuit </WRAP>
  
 The waveform generator should be configured for a 1 KHz triangle wave with 3 volt amplitude and 1.5V offset. The input of scope channel 2 (2+) is used to measure the stabilized output current at the collector of Q2. The waveform generator should be configured for a 1 KHz triangle wave with 3 volt amplitude and 1.5V offset. The input of scope channel 2 (2+) is used to measure the stabilized output current at the collector of Q2.
Line 29: Line 33:
  
 The zero gain amplifier can be used to create a stabilized current source. Because the voltage seen at the collector of transistor Q<sub>1</sub> is now more constant with changes in the input supply voltage as represented by AWG1, it can be used as the base voltage of Q<sub>2</sub> to produce a much more constant current in transistor Q<sub>2</sub>. The zero gain amplifier can be used to create a stabilized current source. Because the voltage seen at the collector of transistor Q<sub>1</sub> is now more constant with changes in the input supply voltage as represented by AWG1, it can be used as the base voltage of Q<sub>2</sub> to produce a much more constant current in transistor Q<sub>2</sub>.
 +
 +<WRAP centeralign>{{:university:courses:electronics:bjt_stabilized_cs-wav.png?500|}}</WRAP>
 +
 +<WRAP centeralign> Figure 3 Q<sub>2</sub> collector voltage vs. W1 voltage </WRAP>
 +
 +<WRAP centeralign>{{:university:courses:electronics:bjt_stabilized_cs-wav2.png?500|}}</WRAP>
 +
 +<WRAP centeralign> Figure 4 Q<sub>2</sub> collector current vs. W1 voltage Scopy plot </WRAP>
  
 {{ :university:courses:electronics:a8_f2.png?500 |}} {{ :university:courses:electronics:a8_f2.png?500 |}}
  
-<WRAP centeralign> Figure Q<sub>2</sub> collector current vs. W1 voltage </WRAP>+<WRAP centeralign> Figure Q<sub>2</sub> collector current vs. W1 voltage Excel plot</WRAP>
  
 ===== Questions: ===== ===== Questions: =====
university/courses/electronics/electronics-lab-8.txt · Last modified: 25 Jun 2020 22:07 by 127.0.0.1