university:courses:electronics:electronics-lab-21 [23 Mar 2017 16:34] – [Materials:] Doug Merceruniversity:courses:electronics:electronics-lab-21 [24 Jul 2017 16:08] – change amplitude value to peak-peak Antoniu Miclaus
Line 26: Line 26:
 ===== Directions: ===== ===== Directions: =====
  
-First build the simple example shown figure 2 to test the input to output transfer function of the simple CMOS amplifier. The green boxes indicate connections to the connector on Analog Discovery. Connect Vp (+5V) power to V<sub>CC</sub> (pin 14) and ground to GND (pin 7). Connect the output of the waveform generator to one of the inverter inputs (pin 1) along with scope input 1+ and connect the inverter output (pin 2) to scope input 2+. +First build the simple example shown figure 2 to test the input to output transfer function of the simple CMOS amplifier. The green boxes indicate connections to the connector on The ADALM2000. Connect Vp (+5V) power to V<sub>CC</sub> (pin 14) and ground to GND (pin 7). Connect the output of the waveform generator to one of the inverter inputs (pin 1) along with scope input 1+ and connect the inverter output (pin 2) to scope input 2+. 
  
 {{ :university:courses:electronics:a20_f2.png?500 |}} {{ :university:courses:electronics:a20_f2.png?500 |}}
Line 40: Line 40:
 ===== Hardware Setup: ===== ===== Hardware Setup: =====
  
-Configure the waveform generator for a 1 KHz triangle wave with 2V amplitude and 2.5V offset. Both scope channels should be set to 1V/Div.+Configure the waveform generator for a 1 KHz triangle wave with 4V amplitude and 2.5V offset. Both scope channels should be set to 1V/Div.
  
 ===== Procedure: ===== ===== Procedure: =====
Line 56: Line 56:
 ===== Hardware Setup: ===== ===== Hardware Setup: =====
  
-Configure the Network (Bode) analyzer for 2 log decades, end frequency of 100 KHz, a max gain of 2X, run time of 10 sec, offset of 0 V and an amplitude of V. Run a single sweep and save the data to a file.+Configure the Network (Bode) analyzer for 2 log decades, end frequency of 100 KHz, a max gain of 2X, run time of 10 sec, offset of 0 V and an amplitude of V. Run a single sweep and save the data to a file.
  
 =====Question: ===== =====Question: =====