 ===== Hardware Setup: ===== ===== Hardware Setup: =====
  
-The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude and 0 offset. The Single ended input of scope channel 2 (2+) is used to measure the voltage at the emitter. The Scope configured with channel 1+ connected to display the AWG generator output. When measuring the input to output error, channel 2 of the scope should be connected to display 2+ and 2- differential.+The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude and 0 offset. The Single ended input of scope channel 2 (2+) is used to measure the voltage at the emitter. The Scope configured with channel 1+ connected to display the AWG generator output. When measuring the input to output error, channel 2 of the scope should be connected to display 2+ and 2- differential.
  
 {{ :university:courses:electronics:a11_f2.png?500 |}} {{ :university:courses:electronics:a11_f2.png?500 |}}
Line 71: Line 71:
 ===== Hardware Setup: ===== ===== Hardware Setup: =====
  
-The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude with the offset set equal to minus the V<sub>BE</sub> of Q<sub>1</sub> ( approximately -0.65V ). This injects a +/- 0.1mA (1V/10KΩ) current into Q<sub>1</sub>‘s emitter. Scope input 2+ measures the change in voltage seen at the emitter.+The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude with the offset set equal to minus the V<sub>BE</sub> of Q<sub>1</sub> ( approximately -0.65V ). This injects a +/- 0.1mA (1V/10KΩ) current into Q<sub>1</sub>‘s emitter. Scope input 2+ measures the change in voltage seen at the emitter.
  
 ===== Procedure: ===== ===== Procedure: =====
Line 98: Line 98:
 ===== Hardware Setup: ===== ===== Hardware Setup: =====
  
-The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude with the offset set equal to 0. Scope input channel 2 is set to 500mV / Div.+The waveform generator should be configured for a 1 KHz Sine wave with volt amplitude with the offset set equal to 0. Scope input channel 2 is set to 500mV / Div.
  
 ===== Procedure: ===== ===== Procedure: =====