DC Input No Mips

Description

The DC Input No MIPs Block is a parameter value write utility which can write directly to any parameter. The block's controls allow the value and the format to be set. There are 32/28 available bits which can be used to represent decimal values depends on the SigmaDSP.

Targets Supported

NameADSP-214xxADSP-215xx/ADSP-SC5xxADAU145x/146x
DC Input No MIPs NA NA Sample


Pins

Configurable Parameters

GUI Parameter NameDefault ValueRangeFunction Description
DCValue00 to 2147483647This control gives the DC, direct current, signal(a constant numeric value)
IntegerBits5/80 to 32 (Only for SigmaDSP)This control decides the range of DC control
DecimalBits23/240 to 32(Only for SigmaDSP)This control decides the range of DC control


DSP Parameters

Parameter NameDescriptionADSP-214xx/SC5xx/215xxADAU145x/146x
DCValueDC, direct current, signal(a constant numeric value)FloatFormat specified in UI