Line 1: | Line 1: | ||
+ | [[resources/ | ||
+ | ====== Toggle Counter ====== | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | ===== Description ===== | ||
+ | \\ | ||
+ | The Toggle Counter cell counts the number of edges seen on its input pin and outputs the count as a 32.0 integer value. The toggle detection can be set to detect rising or falling edges on the input. | ||
+ | \\ | ||
+ | ===== Usage ===== | ||
+ | \\ | ||
+ | The toggle counter increments an internal counter each time an edge is detected on the input. Two algorithms exist: one for detecting and counting rising edges, and one for detecting and counting falling edges. | ||
+ | |||
+ | The rising edge counter starts at zero when the program begins. Each time the input detects a rising edge - in any number format - the counter will increment. After the counter exceeds the maximum count value (which can be configured in the GUI), it will reset to zero and resume counting again. | ||
+ | |||
+ | The falling edge counter starts at zero when the program begins. Each time the input detects a falling edge - in any number format - the counter will increment. After the counter exceeds the maximum count value (which can be configured in the GUI), it will reset to zero and resume counting again. | ||
+ | \\ | ||
+ | ===== Targets Supported ===== | ||
+ | ^Name^ADSP-214xx^ADSP-215xx/ | ||
+ | |----------------------------------------|------------------------------------------|--------------------------------------------------|-------------------------------------------| | ||
+ | |Toggle Counter| Not supported | Not supported | Sample| | ||
+ | |||
+ | \\ | ||
+ | ===== Pins ===== | ||
+ | ==== Input==== | ||
+ | ^Name^Type^Description^ | ||
+ | |---------------|-------------------|------------------------------------------------------------| | ||
+ | |Input0|Control|Control Signal input that is detected by the toggle counter| | ||
+ | |Input1|Logic|Connected to a software interface register - reads the last count value at startup| | ||
+ | |||
+ | ==== Output==== | ||
+ | ^Name^Type^Description^ | ||
+ | |---------------|-------------------|-----------------------------------------------------------------------------| | ||
+ | |Output0|Control|Toggle count. Increments by one each time a new edge is detected on the input.| | ||
+ | |Output1|Logic|Other - interface register. Connected to a software interface register - writes the last count value| | ||
+ | |||
+ | \\ | ||
+ | ===== Configurable Parameters ===== | ||
+ | ^GUI Parameter Name^Default Value^Range^Function Description^ | ||
+ | | ---------------------------------------- | ---------------------- | ------------------------------------- | ---------------------------------------- | | ||
+ | |Gain| 3|3 to 100 |Sets the toggle count at which the counter resets to zero| | ||
+ | |IsLin| true | true/false | Setting this value to true indicates the gain is a decimal value, else the value is entered in dB| | ||
+ | \\ | ||
+ | ===== DSP Parameters ===== | ||
+ | ^Parameter Name^Description^ADAU145x/ | ||
+ | |---------------|----------------------------------------------------- |---------------------------------| | ||
+ | |max|The maximum value that the counter can reach. When the counter exceeds this value, it will be reset to zero|Fixed Point 8.24| | ||
+ | |||
+ | \\ | ||
+ | ===== DSP Parameter Computation ===== | ||
+ | \\ | ||
+ | if IsLin ==true | ||
+ | max= Gain | ||
+ | else | ||
+ | max = 10^ (Gain/20) | ||
+ | \\ | ||