Param Read or Write



Description

The parameter Read module can be used to read any parameter in the schematic and get the value in the output pin. The parameter Write block allows user to update the module's parameter value dynamically. The selected parameters are updated with the value coming from the input pins

Configuration

The selection of the parameter will be enabled only when the schematic compilation is completed successfully. The user can select the module for which the parameter needs to be updated/Read. After selecting the module, the parameter within the module should be selected for which value should be updated. The value of the selected parameter will be updated with the given input value for each sample once the schematic is downloaded. User can also change the parameter selection when the schematic is downloaded. It will start updating/Read the newly selected parameter once the parameter selection window is closed.

Variants

  1. Parameter Read
  2. Parameter Write


Targets Supported

Name ADSP-214xx ADSP-215xx/SC5xx ADAU145x/146x
—————————— ——————-- ——————————-- —————————-
Param Read B B NA
Param Write B B NA


Pins

Input

Name Type Description
———————- ————-- ———————-
Input Control Input Channel (Only for ParamWrite)

Output

Name Type Description
———————- ————-- ———————-
Output Control Output Channel (Only for ParamRead)


Configurable Parameters

GUI Parameter Default Value Range Function Description
—————————————- ———————- —————— —————————————-
Module NA NA Name of the module in the schematic
Parameter NA NA Name of the parameter in the selected module
Address 0 NA Address of the parameter. If the user wants to enter the address directly Select the Address mode
Mode Parameter Parameter / Address User can select the mode
Format Float Float / Int32 Data type of the parameter


DSP Parameters

Parameter Name Description ADSP-214xx/SC5xx/215xx ADAU145x/146x
—————————————- ———————————————————————————————————- —————————- ——————
Address Address of the parameter Integer32 NA
Offset This offset is added to the address, then that is used as the address to read the parameter from Integer32 NA
Type Data type of the parameter Integer32 NA
BaseOffset Used to calculate the address Integer32 NA