ADAU145x / ADAU146x Hardware Setup

Requirements

The following are the list of hardware components required for setting up the demo application.

  • EVAL-ADAU1452MINIZ / EVAL-ADAU1466Z / EVAL-ADAU1467Z.
  • PC/Laptop with a stereo audio out and USB port.
  • EVAL-ADUSB2EBZ USB to SPI converter.
  • Aardvark I2C/SPI Host Adapter
  • Audio cables and USB cables.

Setup

The SigmaStudio+ demonstration setup for ADAU145x and ADAU146x includes a Host PC running SigmaStudio+ which is connected to the evaluation board. The connection is achieved using a USB-to-SPI converter. The EVAL-ADUSB2EBZ or Aardvark I2C/SPI acts as the USB-to-SPI converter, which is connected to the PC through a USB port and to the evaluation board through SPI pins.

Connections


Connect EVAL board to PC using USBi

The EVAL-ADUSB2EBZ (hereafter referred to as the ‘USBi’) has a 10 pin socket. This is connected to SPI CONTROL PORT/CONTROL PORT header on the board.

Connect EZ-Board to PC using Aardvark I2C/SPI Host Adapter

Connect Aardvark I2C/SPI Host Adapter to the PC running SigmaStudio using a USB cable. Aardvark I2C/SPI Host Adapter has a 10 pin socket. This is connected to SPI CONTROL PORT/CONTROL PORT header on the board.

Connect Audio Input and Output

Connect an analog audio source and headphones/speakers to the audio ports on the EVAL board.

Connect Power to the EVAL Board

Connect the power and reset the board by pressing the ‘RESET’ button on the EVAL Board.