resources:tools-software:sigmastudio:faq [05 Jan 2023 07:43] – [Modules Q & A] Sowmya devi Rresources:tools-software:sigmastudio:faq [15 Feb 2023 13:34] (current) Sakthivel Perumal
Line 616: Line 616:
 **Q: Why is parameter tuning not working for custom plugin?** **Q: Why is parameter tuning not working for custom plugin?**
  
-A: Default parameters should be added into the custom plugin .xml file +A: 
-   Runtime parameters should be added in algorithm designer+  * Default parameters should be added into the custom plugin .xml file 
 +  Runtime parameters should be added in algorithm designer
 \\ \\
-{{standardindpic2.png}}\\+{{:resources:tools-software:sigmastudio:image2023-1-5_11-32-46.png?400}}\\
 \\ \\
 +  * The runtime parameter should be assigned to default parameters as shown below,
 +\\
 +{{:resources:tools-software:sigmastudio:image2023-1-5_11-51-58.png?400|}}\\
 +\\
 +  * The runtime parameter should be assigned to UI controls as shown below,
 +Step 1: Select and right click on the UI control, click on “Assign” option
 +\\
 +{{:resources:tools-software:sigmastudio:image2023-1-5_11-52-38.png?400|}}\\
 +\\
 +Step 2: In Control Action drop down select “ValueChanged”
 +\\
 +{{:resources:tools-software:sigmastudio:image2023-1-5_11-53-54.png?400|}}\\
 +\\
 +Step 3: Select the runtime parameter for corresponding UI control and click on apply
 +\\
 +{{:resources:tools-software:sigmastudio:image2023-1-5_11-54-38.png?400|}}\\
 +\\
 +Step 4: Review the UI control settings in properties window for Minimum, Maximum, Values
 +\\
 +{{:resources:tools-software:sigmastudio:image2023-1-5_11-55-35.png?400|}}\\
 +\\
 +These steps to be followed for every UI control to avoid runtime parameter tuning issues.
  
 ====== SigmaStudio for SHARC Host Packeting Q & A ====== ====== SigmaStudio for SHARC Host Packeting Q & A ======
Line 628: Line 651:
 A: Please refer to the “AE_42_SS4G_HostControllerGuide.pdf” document under “C:\Analog Devices\SoftwareModules\SigmaStudioForSHARC-SH-Rel4.7.0\Docs” folder. A: Please refer to the “AE_42_SS4G_HostControllerGuide.pdf” document under “C:\Analog Devices\SoftwareModules\SigmaStudioForSHARC-SH-Rel4.7.0\Docs” folder.
  
-**Q: What is the default USBi speed?**+**Q: What is the default SPI and I2C speed on USBi?** 
 + 
 +A: The default SPI speed on USBi in SigmaStudio host is approximately 732 kHz. The default I2C speed on USBi in SigmaStudio host is approximately 84 kHz.
  
-AThe default SPI speed for USBi in SigmaStudio host is approximately 732 kHz.+**QWhether the default SPI or I2C speed on USBi configurable?**
  
 +A: No the speed can't be configured for SPI or I2C on USBi.
 +     
 **Q: What is the SPI baud rate supported by SigmaStudio Host?** **Q: What is the SPI baud rate supported by SigmaStudio Host?**
  