resources:eval:user-guides:adrv9029:dpd_error_troubleshooting [11 Mar 2024 08:16] – Adding ADI_ADRV9025_DPD_UNITY_MODEL_UNAVAILABLE_ERROR to the list of errors Anand Kumar | resources:eval:user-guides:adrv9029:dpd_error_troubleshooting [25 Mar 2024 07:07] (current) – Added Recovery action for "Unknown RPC error" Ramarao Bitra | ||
---|---|---|---|
Line 225: | Line 225: | ||
* Inspect the DPD model and re-assign any DPD model entries assigned to LUT numbers 28, 29 or 30. | * Inspect the DPD model and re-assign any DPD model entries assigned to LUT numbers 28, 29 or 30. | ||
* The DPD Model entry LUT assignment can be found under the encircled column in a DPD model file as shown below. {{: | * The DPD Model entry LUT assignment can be found under the encircled column in a DPD model file as shown below. {{: | ||
+ | \\ | ||
+ | === ADI_ADRV9025_DPD_UNKNOWN_RPC_ERROR === | ||
+ | **ROOT CAUSE** : It is very unlikely that the transceiver gets into this state and ARM entered into an unknown error state. | ||
+ | **RECOMMENDED RECOVERY ACTIONS** | ||
+ | * Reset the Transceiver which means complete re-initialization of the system. | ||
+ | |||
\\ | \\ | ||