Wiki

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
resources:eval:user-guides:adbt1000 [02 Nov 2021 12:47] – [Bill of Materials] Frances de la Ramaresources:eval:user-guides:adbt1000 [17 Nov 2021 01:38] (current) – Figure 5 Edit Frances de la Rama
Line 52: Line 52:
   - Connect the Device Under Test (electronic load or battery) to connector P5 on the switching power module. {{ :resources:eval:user-guides:adbt1000_two_wire_load_connection.jpg?300 |2-wire Battery Connection}} <WRAP centeralign> //Figure 3. 2-wire Battery Connection//</WRAP>   - Connect the Device Under Test (electronic load or battery) to connector P5 on the switching power module. {{ :resources:eval:user-guides:adbt1000_two_wire_load_connection.jpg?300 |2-wire Battery Connection}} <WRAP centeralign> //Figure 3. 2-wire Battery Connection//</WRAP>
   - Connect the SDP-S controller to the System Control Board. {{ :resources:eval:user-guides:adbt1000_sdp_s_connection.jpg?300 | SDP-S Connection}} <WRAP centeralign> //Figure 4. SDP-S Connection//</WRAP>   - Connect the SDP-S controller to the System Control Board. {{ :resources:eval:user-guides:adbt1000_sdp_s_connection.jpg?300 | SDP-S Connection}} <WRAP centeralign> //Figure 4. SDP-S Connection//</WRAP>
-  - Connect power supplies of +/-15V to P5 of the system control board for the Auxiliary Power Input. {{ :resources:eval:user-guides:adbt1000_sdp_s_connection.jpg?300 |}} <WRAP centeralign> //Figure 5. Auxiliary Power Supply Connection//</WRAP>+  - Connect power supplies of +/-15V to P5 of the system control board for the Auxiliary Power Input. {{ :resources:eval:user-guides:adbt1000_auxiliary_power_supply_connection.jpg?300 |}} <WRAP centeralign> //Figure 5. Auxiliary Power Supply Connection//</WRAP>
   - Connect power supplies for the DC bus voltage to P2 of the system control board. Connect an electronic load in parallel. Set the electronic load to CV mode at a level about 200mV above the DC bus voltage. {{ :resources:eval:user-guides:dc_bus_connection.jpg?300 | DC Bus Connection}} <WRAP centeralign> //Figure 6. DC Bus Connection//</WRAP>   - Connect power supplies for the DC bus voltage to P2 of the system control board. Connect an electronic load in parallel. Set the electronic load to CV mode at a level about 200mV above the DC bus voltage. {{ :resources:eval:user-guides:dc_bus_connection.jpg?300 | DC Bus Connection}} <WRAP centeralign> //Figure 6. DC Bus Connection//</WRAP>
   - Turn on Auxiliary power, then DC bus voltage, then electronic load at DC bus.    - Turn on Auxiliary power, then DC bus voltage, then electronic load at DC bus. 
Line 319: Line 319:
 {{ :resources:eval:user-guides:adbt1000_layout_scb_layer_6_secondary.svg?600 |}} <WRAP centeralign> //Figure 72.  System Control Board Layer 6 Secondary//</WRAP> \\ {{ :resources:eval:user-guides:adbt1000_layout_scb_layer_6_secondary.svg?600 |}} <WRAP centeralign> //Figure 72.  System Control Board Layer 6 Secondary//</WRAP> \\
  
-==== System Power Module ====+==== Switching Power Module ====
 {{ :resources:eval:user-guides:adbt1000_schematic_system_power_module.svg?800 |}} <WRAP centeralign> //Figure 73.  System Power Module//</WRAP> \\  {{ :resources:eval:user-guides:adbt1000_schematic_system_power_module.svg?800 |}} <WRAP centeralign> //Figure 73.  System Power Module//</WRAP> \\ 
 {{ :resources:eval:user-guides:adbt1000_schematic_current_sense_and_socket_connections.svg?600 |}} <WRAP centeralign> //Figure 74.  Current Sense and Socket Connection//</WRAP> \\  {{ :resources:eval:user-guides:adbt1000_schematic_current_sense_and_socket_connections.svg?600 |}} <WRAP centeralign> //Figure 74.  Current Sense and Socket Connection//</WRAP> \\ 
Line 329: Line 329:
  
 ===== Bill of Materials ===== ===== Bill of Materials =====
-<WRAP centeralign> **Table 3.  System Control Board**</WRAP>+<WRAP centeralign> **Table 5.  System Control Board**</WRAP>
 {{ :resources:eval:user-guides:adbt100_bom_scb2.1.svg?797 |}}  {{ :resources:eval:user-guides:adbt100_bom_scb2.1.svg?797 |}} 
 {{ :resources:eval:user-guides:adbt1000_bom_scb3.svg?795 |}} {{ :resources:eval:user-guides:adbt1000_bom_scb3.svg?795 |}}
Line 335: Line 335:
 {{ :resources:eval:user-guides:adbt1000_bom_scb5.svg?800 |}} {{ :resources:eval:user-guides:adbt1000_bom_scb5.svg?800 |}}
 {{ :resources:eval:user-guides:adbt1000_bom_scb6.svg?800 |}} {{ :resources:eval:user-guides:adbt1000_bom_scb6.svg?800 |}}
-{{ :resources:eval:user-guides:adbt1000_bom_scb7.svg?800 |}}+{{ :resources:eval:user-guides:adbt1000_bom_scb7.svg?800 |}} \\ 
 +\\ 
 + 
 +<WRAP centeralign> **Table 6.  Switching Power Module**</WRAP> 
 +{{ :resources:eval:user-guides:adbt1000_bom_spm1.1.svg?800 |}} 
 +{{ :resources:eval:user-guides:adbt1000_bom_spm2.svg?800 |}} 
 +{{ :resources:eval:user-guides:adbt1000_bom_spm3.svg?800 |}} \\ 
 + 
 +{{ :resources:eval:user-guides:adbt1000_copyright1.svg?800 |}}
  
resources/eval/user-guides/adbt1000.1635853672.txt.gz · Last modified: 02 Nov 2021 12:47 by Frances de la Rama