resources:eval:user-guides:ad-fmcmotcon1-ebz:hardware:dyno [09 Jul 2014 14:52] – [Downloads] Andrei Cozmaresources:eval:user-guides:ad-fmcmotcon1-ebz:hardware:dyno [10 Jul 2014 14:07] – updated discovery section Mihai Bancisor
Line 43: Line 43:
 | :::                        | Change duty cycle step.\\ \\ \\ | | :::                        | Change duty cycle step.\\ \\ \\ |
 | :::                        | About.\\ \\ \\ | | :::                        | About.\\ \\ \\ |
 +
 +|< 100% 100% >|
 +^  ^
 +===== Analog Discovery™  ===== 
 +In order interface the Dyno with the Analog Discovery™ USB Oscilloscope:
 +  * Slide switch S2 to EXT_CTRL position
 +  * Insert the Analog Discovery™ in P1 the connector(with the Analog Devices logo facing the user) 
 +
 +{{:resources:eval:user-guides:ad-fmcmotcon1-ebz:hardware:dyno_discovery_control.JPG?400|Dynamometer Drive System}}
 +
 +Two software packages are available for interfacing with Analog Discovery™:
 +  *[[http://www.digilentinc.com/Products/Detail.cfm?NavPath=2,66,849&Prod=WAVEFORMS|Digilent® WaveForms™]]\\
 +  *[[http://www.mathworks.co.uk/help/daq/examples/getting-started-acquiring-data-with-digilent-analog-discovery.html|MathWorks Analog Discovery toolbox ]]\\
 +
 +The signals available to the  Analog Discovery™ are:
 +^ Dyno Signal ^ Analog Discovery channel ^ Description ^ 
 +| I_A | Scope Channel 1 Positive | Phase A motor current (185mv/A) | 
 +| I_B | Scope Channel 2 Positive | Phase B motor current (185mv/A) | 
 +| PWM1 | Digital Channel 0 | Phase A PWM (3.3V levels) | 
 +| PWM2 | Digital Channel 2 | Phase B PWM (3.3V levels) |
 +| PWM3 | Digital Channel 2 | Phase C PWM (3.3V levels) |
  
 |< 100% 100% >| |< 100% 100% >|
resources/eval/user-guides/ad-fmcmotcon1-ebz/hardware/dyno.txt · Last modified: 10 Feb 2021 04:43 by Robin Getz