 The large but still finite 1 megaohm input resistance of the scope channel will load down the peak voltage generated by the transducer. Remove the connection to scope channel 1 and again rapidly flick the transducer. The DC voltage seen at the output should be significantly higher now. The large but still finite 1 megaohm input resistance of the scope channel will load down the peak voltage generated by the transducer. Remove the connection to scope channel 1 and again rapidly flick the transducer. The DC voltage seen at the output should be significantly higher now.
  
-{{ :​university:​courses:​electronics:​aeh_f4.png?550 |}}+{{:​university:​courses:​electronics:​ener_harv_plot.png|}}
  
 <WRAP centeralign>​ Figure 3 Scope Screen shot when flicking transducer rapidly </​WRAP>​ <WRAP centeralign>​ Figure 3 Scope Screen shot when flicking transducer rapidly </​WRAP>​