Wiki

This version (17 Sep 2022 06:50) was approved by Angu Sewa.The Previously approved version (13 May 2021 08:29) is available.Diff

Click here to return to the Sources page

DC Input Entry

Description

The DC Input Block allows you to generate a DC, direct current, signal(a constant numerical value). This Block can be used to generate control signals for Multiplexers and Lookup Tables. The block's controls allow the DC value and the format to be set. There are 32/28 available bits which can be used to represent decimal values depends on the SigmaDSP.

Targets Supported

NameADSP-214xxADSP-215xx/ADSP-SC5xxADAU145x/146x
—————————————-——————————————————————————————--——————————————-
DC Input Entry Block and Sample Block and Sample Sample


Pins

Output

NameTypeDescription
——————————— ———————————- ————————————--
OutputControlOutput channel 0


Configurable Parameters

GUI Parameter NameDefault ValueRangeFunction Description
—————————————- ———————- ———————————— ———————————————————--
DCValue00 to 2147483647This control gives the DC, direct current, signal(a constant numeric value)
IntegerBits5/80 to 32 (Only for SigmaDSP)This control decides the range of DC control
DecimalBits23/240 to 32(Only for SigmaDSP)This control decides the range of DC control


DSP Parameters

Parameter NameDescriptionADSP-214xx/SC5xx/215xxADAU145x/146x
—————————-- ——————————————————————— ———————————————————————————
DCValueDC, direct current, signal(a constant numeric value)FloatFormat specified in UI


resources/tools-software/sigmastudiov2/modules/sources/dcinputentry.txt · Last modified: 17 Sep 2022 06:50 by Angu Sewa