Description

The RMS w/Ext Detector Compressor block computes the RMS level of the control signal and applies the compressor gain to the input signal based on the RMS value.

Targets Supported

NameADSP-214xx(Sample)ADSP-214xx(Block)ADSP-215xx/ADSP-SC5xx(Sample)ADSP-215xx/ADSP-SC5xx(Block)
RMS w/Ext Detector Yes YesYes Yes


Pins

Input

NameTypeDescription
ExtDetectorInputControlDetermines the amount of compressor gain applied to the input signal
Input1AudioInput channel1

Output

NameTypeDescription
Output1AudioOutput channel1


Configurable Parameters

GUI Parameter NameDefault ValueRangeFunction Description
TimeConstant121 1 to 8686 dB/sControls the time constant (TC) in dB/second that is used for calculating the RMS input value. The time constant determines how rapidly the compressor will respond to input signal level changes, e.g. the “Attack” time.
Hold0 ms0 to 2000 msControls the time (in ms) the compressor maintains its current output gain setting before it starts decreasing as the input level decrease.
Decay 10 dB/s 0 to 10000 dB/sControls the rate at which the compressor gain decreases in response to decrease in the input signal level, e.g. the “Release” time.
SoftKneeFalseTrue/FalseSoft-knee lets the compressor ease into action, making a less-abrupt change from unprocessed signal to compressed signal. If it is not activated, the default is hard-knee behavior, in which compression rate reduces or increases abruptly with the threshold level.
TableAll values are 1-Table values are the gain points used to apply for input signal level
IsDBpsTrueTrue/False Enable /Disable the control's Decay and TimeConstant either in dB or linear
NumChannels11 to 20Number of input and output channels. Change in this value requires re-compilation


DSP Parameters

Parameter NameDescriptionADSP-214xx/SC5xx/215xx
TimeConstantRMS time constant valueFloat
HoldHold valueFloat
DecayDecay valueFloat
TableTable values Float
LogCoeff Constant coefficientsFloat


DSP Parameter Computation


TimeConstant = Abs(1 - 10^(TimeConstant/(10 * (FS + 0.0000001)))), Where TimeConstant is 20000/TimeConstant in dBps
Decay = (20000/Decay)/(FS + 0.0000001) (When Decay is in dBps) or Decay/(FS + 0.0000001) (When Decay is in linear)
Hold = FS * Hold/1000
Where FS is the sampling rate