resources:tools-software:sigmastudiov2:modules:basic:minvaluehold [04 Feb 2020 10:31] – Added an image Sanjeeva Reddyresources:tools-software:sigmastudiov2:modules:basic:minvaluehold [13 Sep 2022 11:33] (current) – Updates Image Angu Sewa
Line 2: Line 2:
 ====== Min Value Hold ====== ====== Min Value Hold ======
 \\ \\
-{{:resources:tools-software:sigmastudiov2:modules:basic:minhold.png}}+{{:resources:tools-software:sigmastudiov2:modules:basic:minholdnew.png?nolink}}
 ===== Description ===== ===== Description =====
-The MinValueHold block monitors one (or more) input(s) and routes the minimum value of the input to the output. This block held's the min value while the control input is 1 and reset the min value while the control input is 0.+The MinValueHold block monitors one (or more) input(s) and routes the minimum value of the input to the output. This block hold's the min value while the control input is 1 and reset the min value while the control input is 0.
 \\ \\
 ===== Targets Supported ===== ===== Targets Supported =====
-^Name^ADSP-214xx(Sample)^ADSP-214xx(Block)^ADSP-215xx/ADSP-SC5xx(Sample)^ADSP-215xx/ADSP-SC5xx(Block)+^ Name            ^ ADSP-214xx ^ ADSP-215xx/SC5xx ^ ADAU145x/146x 
-|MinValueHoldYes Yes|Yes| Yes+------------------------------------------------------------ -------------------- -------------------------------- ---------------------------- 
-\\+|MinValueHold| B/S | B/S | B/S |
 ===== Pins ===== ===== Pins =====
 ==== Input ==== ==== Input ====
 ^Name^Type^Description^ ^Name^Type^Description^
 +|------------------------------|------------------------------------------------------------|------------------------------|
 |Reset|Control|Resets the minimum value| |Reset|Control|Resets the minimum value|
-|Input0|Audio|Input channel 0|+|Input<fc #ff0000>X</fc> | Audio | Input channel X| 
 +Note: 
 +     * <fc #ff0000>X</fc> - Channel Index 
 ==== Output ==== ==== Output ====
 ^Name^Type^Description^ ^Name^Type^Description^
-|Output0|Audio|Output channel 0|+|------------------------------|------------------------------------------------------------|------------------------------| 
 +|Output | Audio | Output channel|
 \\ \\
 ===== Configurable Parameters ===== ===== Configurable Parameters =====
 ^GUI Parameter Name^Default Value^Range^Function Description^ ^GUI Parameter Name^Default Value^Range^Function Description^
 +|------------------------------|---------------------------|----------------------------|----------------------------------------------------------|
 |NumChannels|1| 20|Number of input and output channels. Change in this value requires re-compilation| |NumChannels|1| 20|Number of input and output channels. Change in this value requires re-compilation|
-\\ 
-===== DSP Parameters ===== 
-No DSP parameters 
 \\ \\
resources/tools-software/sigmastudiov2/modules/basic/minvaluehold.txt · Last modified: 13 Sep 2022 11:33 by Angu Sewa