Absolute Max Value Hold


Description

The AbsMaxValueHold block monitors one (or more) input(s) and routes the absolute max value of the input to the output. This block helds the absolute max value while the control input is 1 and reset the absolute max value while the control input is 0.

Targets Supported

Name ADSP-214xx ADSP-215xx/SC5xx ADAU145x/146x
———————————————————— ——————-- ——————————-- —————————-
AbsMaxValueHold B/S B/S S


Pins

Input

NameTypeDescription
————————————————————————————————————————
ResetControlResets the absolute maximum value
InputXAudioInput channel X

Note:

  • X - Channel Index

Output

NameTypeDescription
————————————————————————————————————————
Output Audio Output channel

Configurable Parameters

GUI Parameter NameDefault ValueRangeFunction Description
————————————————————————————-———————————————————-
NumChannels1 20Number of input and output channels. Change in this value requires re-compilation