Voice Activity Detector Flag


Description

VAD Flag takes the Modulation Index and compares it to a threshold value. If the threshold value is met for the designated amount of time, the output flag is set high, otherwise it is low.

Targets Supported

Name ADSP-214xx ADSP-215xx/SC5xx ADAU145x/146x
————————————-- ——————-- ——————————-- —————————-
VAD Flag NA NA S


Pins

Input

Name Type Description
———————- ————-- ———————-
ModulationIndex Control Modulation Index

Output

Name Type Description
—————————- ————-- ———————-
ConditionFlag Control 0 or 1 output determining if speech is present or not


Configurable Parameters

GUI Parameter Default Value Range Function Description
—————————————- ———————- —————— —————————————-
Threshold -30 -96 - 24 dB value for comparison with Modulation Index
Count 250 1 - 10000 Time value in (ms) for condition to be met before setting flag high


DSP Parameters

Parameter Name Description ADSP-214xx/SC5xx/215xx ADAU145x/146x
—————————————- —————————————————————- —————————————- —————————-
thresh Threshold value NA 8.24 Format
count time before setting the flag high NA Integer