Wiki

This version (31 Aug 2016 07:26) was approved by Venkatesan Krishnamoorthy.The Previously approved version (26 Apr 2016 06:28) is available.Diff

Master Control Port Status (ADAU145x)

Click here to return to the Master Control Port page


The master control port Status block sends out the Master control port status in the output pins. Master control errors can be cleared by setting input pin to non-zero value.

Input Pins

NameFormat [int/dec] - [control/audio]Function Description
Pin 0: Master Control Port Error Cleardecimal - controlAny non -zero value in the input clears the error.

Output Pins

NameFormat [int/dec] - [control/audio]Function Description
Pin 0: Master Control Port Statusdecimal - controlOutputs 1 while the Master control port is busy, otherwise outputs 0
Pin 1: Master Control Port Errordecimal - controlIt is a 2 bit value. Bit-0 is set if I2C error is encountered. Bit-1 is set when timeout error occurred.
resources/tools-software/sigmastudio/toolbox/mastercontrolport/mastercontrolportstatus.txt · Last modified: 31 Aug 2016 07:25 by Venkatesan Krishnamoorthy