Wiki

This version (21 Jun 2012 17:11) was approved by William Jahn.The Previously approved version (21 Jun 2012 17:10) is available.Diff

AB In / CD Out Condition

Click here to return to the Basic DSP page


This algorithm works only for DSPs with a conditional instruction.

The AB In / CD Out Condition block lets you compare the sample-by-sample level of two incoming signals (AB) and output the sample of one of two new signals (CD), depending on the condition.

Click the blue icon in the block to select what condition you want to execute:

  • greater than
  • less than
  • greater than or equal to
  • less than or equal to.

When the condition is met, your output sample is C; otherwise it's D.

resources/tools-software/sigmastudio/toolbox/basicdsp/abincdoutcondition.txt · Last modified: 21 Jun 2012 17:11 by William Jahn