-===== ADIS16130 EVALUATION ON THE EVAL-ADIS =====+f===== ADIS16130 EVALUATION ON THE EVAL-ADIS =====
 ==== INTRODUCTION ==== ==== INTRODUCTION ====
 The purpose of this Wiki Guide is to describe an approach to use for evaluating the [[adi>ADIS16130|ADIS16130]] on the [[adi>EVAL-ADIS|EVAL-ADIS]] evaluation system.  Although the [[adi>ADIS16130|ADIS16130]] package and electrical connector would support physical connection with the [[adi>EVAL-ADIS|EVAL-ADIS]], its pin assignment, SPI protocol, data format and operation prevent compatibility with the IMU Evaluation software package.   The purpose of this Wiki Guide is to describe an approach to use for evaluating the [[adi>ADIS16130|ADIS16130]] on the [[adi>EVAL-ADIS|EVAL-ADIS]] evaluation system.  Although the [[adi>ADIS16130|ADIS16130]] package and electrical connector would support physical connection with the [[adi>EVAL-ADIS|EVAL-ADIS]], its pin assignment, SPI protocol, data format and operation prevent compatibility with the IMU Evaluation software package.  
Line 204: Line 204:
  
  
-Take note of the clamps that are on the interface board, but not on the [[adi>adis16130||ADIS16130]].  In some cases, clamping the [[adi>adsi16130|ADIS16130]] down to the board will be necessary, due to the vibration in the oven.  This was not important for this exercise, but can be influential when developing fixtures for calibration systems. +Take note of the clamps that are on the interface board, but not on the [[adi>adis16130||ADIS16130]].  In some cases, clamping the [[adi>adis16130|ADIS16130]] down to the board will be necessary, due to the vibration in the oven.  This was not important for this exercise, but can be influential when developing fixtures for calibration systems. 
  
 The following table illustrates the thermal profile for the temperature chamber for this experiment. For those who are developing calibration systems, the dwell times and ramp rates are likely to be an area for application-specific optimization.   The following table illustrates the thermal profile for the temperature chamber for this experiment. For those who are developing calibration systems, the dwell times and ramp rates are likely to be an area for application-specific optimization.  