resources:eval:user-guides:ad-fmcmotcon1-ebz:quickstart:lv_setup_guide [21 Feb 2014 14:53] – add the last step(release P2, then press S1) for starting the motor Lucian Sinresources:eval:user-guides:ad-fmcmotcon1-ebz:quickstart:lv_setup_guide [12 Sep 2014 13:13] – [Getting Started] Andrei Cozma
Line 24: Line 24:
   * Connect the Low voltage drive board to the Controller board.   * Connect the Low voltage drive board to the Controller board.
   * Connect the Controller + Drive boards assembly to FMC connector of the ZedBoard   * Connect the Controller + Drive boards assembly to FMC connector of the ZedBoard
-  * Insert the 6 pin Hall connector into P7 - pin 1 is the empty slot of the Hall connector+  * Insert the 6 pin Hall connector into P7 - pin 1 is the empty slot of the Hall connector. In case an encoder is used there is a one to one corespondence of the encoder's pins to the pins of the P7 connector.
 {{ :resources:eval:user-guides:ad-fmcmotcon1-ebz:hardware:hall_connector.jpg?300 |Hall connector }} {{ :resources:eval:user-guides:ad-fmcmotcon1-ebz:hardware:hall_connector.jpg?300 |Hall connector }}
   * Insert the 5V supply in the left side of the DYNAMO-METER DRIVE SYSTEM   * Insert the 5V supply in the left side of the DYNAMO-METER DRIVE SYSTEM
resources/eval/user-guides/ad-fmcmotcon1-ebz/quickstart/lv_setup_guide.txt · Last modified: 10 Feb 2021 04:40 by Robin Getz