resources:eval:adf5610-ace-software-guide [07 May 2021 14:24] – [SWEEP AND HOP] Jude Osemeneresources:eval:adf5610-ace-software-guide [22 Jul 2021 19:19] (current) – [Software Installation Procedures] Jude Osemene
Line 1: Line 1:
-====== EV-ADF5610SD1Z ACE SOFTWARE GUIDE ====== +====== EV-ADF5610SD1Z ACE SOFTWARE USER GUIDE ======
- +
-===== Evaluating ADF5610 Microwave Wideband Synthesizer with Integrated Voltage Controlled Oscillators VCO Using ACE Software =====+
  
 ===== Software Installation Procedures ===== ===== Software Installation Procedures =====
 You can install the EV-ADF5610SD1Z plug-in from the ACE start-up page. You can install the EV-ADF5610SD1Z plug-in from the ACE start-up page.
   * You can install ACE from [[http://www.analog.com/en/design-center/evaluation-hardware-and-software/ace-software.html]].   * You can install ACE from [[http://www.analog.com/en/design-center/evaluation-hardware-and-software/ace-software.html]].
-  * On the ACE start-up page locate and click the **Plug-in Manager** on the Side bar.+  * On the ACE start-up page locate and click the **Plug-in Manager** on the side bar. 
 +  * Select Available Packages from the panel second side bar
   * Search for Board.ADF5610 and install plug-in   * Search for Board.ADF5610 and install plug-in
 +{{ :resources:eval:adf5610.png?direct |}}
 ===== Evaluation Board Set-up ===== ===== Evaluation Board Set-up =====
 To run the plug-in, perform the following steps: To run the plug-in, perform the following steps:
Line 44: Line 43:
 ===== Sweep and Hop Controls ===== ===== Sweep and Hop Controls =====
 **Sweep and Hop Control** lets you perform **Sweep** or **Hop** when **Autocalibration** is enabled or disabled. **Sweep and Hop Control** lets you perform **Sweep** or **Hop** when **Autocalibration** is enabled or disabled.
-===== Sweep =====+==== Sweep ====
   * To sweep between frequencies with **Autocalibration** enabled, first define start VCO frequency, stop VCO frequency and channel spacing. This will start sweep using the frequencies while the **Autocalibration subband table** is populated with the sweep frequencies and subbands.   * To sweep between frequencies with **Autocalibration** enabled, first define start VCO frequency, stop VCO frequency and channel spacing. This will start sweep using the frequencies while the **Autocalibration subband table** is populated with the sweep frequencies and subbands.
   * To sweep using subbands, the **Autocalibration Subbands** table must be populated with the subbands from **Autocalibration sweep**. When Autocalibration is disabled and sweep is started, sweep will be use the subbands on the Autocalibration Subbands table.   * To sweep using subbands, the **Autocalibration Subbands** table must be populated with the subbands from **Autocalibration sweep**. When Autocalibration is disabled and sweep is started, sweep will be use the subbands on the Autocalibration Subbands table.
  
-===== Autocalibration Subbands Table =====+=== Autocalibration Subbands Table ===
 There are three buttons on the top righthand corner of the Autocalibration subband table used to control the data contained in the table.  There are three buttons on the top righthand corner of the Autocalibration subband table used to control the data contained in the table. 
   * The first button is used to import subband data saved in csv file stored in the local directory.    * The first button is used to import subband data saved in csv file stored in the local directory. 
Line 57: Line 56:
 Finally, a subband sweep can be performed at random by using the delete icon on each column to delete a sweep step or define a VCO start frequency and use the add button to add the sweep step to the table. Finally, a subband sweep can be performed at random by using the delete icon on each column to delete a sweep step or define a VCO start frequency and use the add button to add the sweep step to the table.
  
-===== Hop ===== +==== Hop ==== 
-Similar to the Sweep, you can hop between two frequencies or subbands+Similar to the Sweep, you can hop between two frequencies. 
-  * When Autocalibration is active, Hop is performed between frequencies+  * When Autocalibration is active, it automatically calibrates the subband needed for that particular frequency
-  * To hop using subbandsfirst run an Autocalibrate using the **Calibrate** button. This will obtain the start and stop subbands, and disable Autocalibration. You can start hop using the start/stop hop button to hop between subbands.+  * For frequency hop in manual mode, run Autocalibrate using the **Calibrate** button to obtain the start and stop subbands. These subbands are pre-loaded into subbands A and B field, and Autocalibration is deactivatedFrequency hop is then executed with the known subbands loaded into the device.
  